Our engineers have most simplified the usage of the Mironoff M3 stone stove, but at the same time, preserved all the safety.
There is only one damper that regulates the air boost ventilator, the degree of the gas supply and physically increases or decreases the damper hole and the air duct, all at the same time.
There are only three positions possible:
1.      The upper position: the air boost ventilator is in full swing, the gas valve is fully open, the chimney and the air duct have the biggest diameter. To be used for quick warming up of the reactor. switch_400
  2.      The middling position: the air boost ventilator works with coefficient 0.5; the gas valve is half open, the chimney and air ducts are half open. To be used when you take a bath – you can enjoy your steam bath and watch the flames through a panoramic glass: it’s nice and the steam room does not get overheated. switch2_400
  3.      The lower position: the air boost ventilator and the gas valve are switched off, the chimney and air ducts are fully closed. In this mode you can take a steam bath. Also, this mode is used when the steam room is not used. switch3_400
The ashpit below is used only to cleanse from the ashes, and when you want to warm up the steam room quickly. If the ashpit is open, the air boosted with the temperatures 300°C-400°C will partially get into the steam room, thus raising the temperature in the bath house.
The multimedia monitor will show you all the necessary information: the temperature and humidity of the air in the steam room, the concentration of carbon monoxide and oxygen and the temperature of the stone fill and the flame. Should any of those parameters suddenly exceed the critical values, an alarm signal will sound. For instance, when the carbon monoxide concentration exceeds 20 ppm, you’ll hear an alarm signal and the gas valve will be closed. If the ion detector detects no flame in the furnace or should you incidentally close the damper, the gas valve will at once close. The gas supply can be resumed by touching the icon on the touch screen.
All is so simple that even a child will cope with that.
The patented air gate is connected to the air boost charging which lets ventilate the steam room in a matter of one minute without waving your towel – just pull the knob and open the door.The Russian banya and excessive air pressure are inseparable from each other, and that is felt when steam is boosted – it sort of tries to knock out the door in the steam room – otherwise it is hardly possible to obtain the long-lasting, dry steam.In order not to break the microclimate of the Russian steam room, exhaust ventilation is not allowed, otherwise the prepared steam will escape through the chimney. At the same time, input ventilation is necessary to enrich the steam room with oxygen. To that end, we offer you to have, as an option, a Mironoff TV monitor installed, to show you all the necessary data, including humidity, the temperature both in the steam room and the reactor, the concentrations of oxygen, methane, carbon monoxide and alcohol. It will also serve you as a media centre in your steam room. Its in-built cooling system will also function as a clean air booster. If you use the oxygen-generating option, you can have the oxygen concentration increased up to 23%, which is more than in any environmentally pure region of the world.
Taking a steam bath will be easy even for small children.